Wenzhou Kangyuan Electronics Co Ltd

Wenzhou Kangyuan Electronics Co Ltd

86-0577-86486389

Wenzhou Kangyuan Electronics Co Ltd
HomeProductsX Ray TubeStationary Anode TubeOriginal office consumable Ribbons for EPSON

Original office consumable Ribbons for EPSON

  • $520
    ≥1
    Piece/Pieces
Payment Type:
T/T
Incoterm:
FOB
Min. Order:
1 Piece/Pieces
Transportation:
Express
Share:
  • Product Description
Overview
Product Attributes

Model No.XD73-1.0/2.0-125

Place Of OriginChina

Kind Of PowerElectric

Warranty Service1 Year

After-sales ServiceReturn And Replacement

MaterialMetal

Shelf Life1years

Supply Ability & Additional Information

TransportationExpress

Payment TypeT/T

IncotermFOB

Packaging & Delivery
Selling Units:
Piece/Pieces

Original office consumable Ribbons for EPSON 15337/LQ590/15329/FX890

X-ray tube should be able to withstand the maximum working voltage test, the highest peak reverse voltage test, super-voltage test, may not have the spark abnormal phenomenon; X-ray tube should have no crack by insulating for 2 hours under the temperature of -55 ℃ ± 3 ℃ and 85 ℃ ± 3 ℃, its maximum working voltage should not more than above maximum working voltage values in the table; X-ray tube should not have the phenomenon of structure loosen or mechanical damage under the condition of frequency of 4 HZ, the largest displacement of 15 mm, the amplitude of 10 mm and time of 30 min, X-ray tube after the exposure of 10,000, its X-ray dose rate of not less than 0.2838 mC / (kg • s)


l Cooling: Oil cooling.

l Note: 1, X-ray tube must be cleaned and dried before installing. 2, X-ray tube initial use or  re-use after long time no use, should be under aging treatment for five minutes. Aging treatment methods: preheat the filament under rated condition for 5 minutes and back to zero, increase the voltage of the tube to maximum working voltage, control anode current 1 mA, stable for two minutes. In the couse of aging it is found lightning, anode current sharp increase or decrease, should immediately reduce the voltage or shut down high-pressure, breaks for five minutes and then executed aging according to above method once again. 3, X-ray tube works, we must ensure that the oil insulation strength not less than 35 kv/2.5mm, oil not more than 60 ℃. 4, Shutdown, generally should reduce the voltage first, shutdown high pressure and then close the filament voltage.

l Warning: The installation and disassemble shoud be carried out professionals

l Storage: the X-ray tube after packing should be stored in non-corrosive gases and well-ventilated room with temperature of -10 ℃ ~ 40 ℃ and relative humidity not more than 80 percent.

l Warranty period of quality: the packaging X-ray tube complies with the storage and transportation, storage and use under the conditions of the rules, 1year since left from the factory, the product cannot work normally for manufacturing quality problems, the manufacturing company should provide maintenance for users for free, replace parts or products.57W


Product Categories : X Ray Tube > Stationary Anode Tube

Email to this supplier
  • *Subject:
  • *To:
    Ms. zhou min
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsX Ray TubeStationary Anode TubeOriginal office consumable Ribbons for EPSON
Send Inquiry
*
*

Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send